If you are choosing or replacing troughs for a feedlot pen or a stock containment area, the MLA feedlot design manual says to go long, narrow and shallow rather than large and deep, fit a big drainage outlet, and decide where the flushing water will go before the trough is set in place. Chapter 20 of that manual, Water trough design and sewer systems, sets out why, and Agriculture Victoria's containment guidance agrees.
Long, narrow and shallow, not big and deep
The water wasted into the pen with each flushing is minimised by using low volume troughs, and long, narrow, shallow troughs are preferable to large, deep, high volume circular troughs. Most feedlot troughs are rectangular rather than round because they fit along fence lines, are easier to clean inside and to clean around with machinery, and give more linear space than a round trough of the same capacity. Agriculture Victoria says the same for containment areas: a long shallow trough with a smooth internal profile, a gate valve and a large outlet bung makes cleaning quick and efficient.
Work out your drinking length
The manual asks for a minimum of 25 mm per head of linear trough space in normal weather, and 75 mm per head in hot conditions. Available length is the trough length less the length lost to float protection, so measure drinking edge, not overall length. For containment areas, Agriculture Victoria suggests a trough for 500 sheep or 160 cattle would have 8 to 10 metres of accessible trough edge and hold 400 to 600 litres.
The drain is the part people skip
Feedlot troughs are cleaned by flushing out the water and adding more while scrubbing, so the manual requires a large drainage outlet on every trough, placed so water flows away from the trough and preferably into a drain. A sewer system taking flushing water to the drain, or better to the retention pond, is increasingly preferred, and it also takes overflow out of the pen if a float valve breaks or jams.
Troughs are flushed by unscrewing the stand pipe, which opens the discharge bung, so the dirty water, grain and debris leave through the pipe network. Because those pipes clog with stones and grain, the manual wants good slope, more than 1%, no sharp bends, and extra flushing time to clear sediment.
Position in the pen
Two positions are recommended. A trough in the fence line between pens is shared by both pens, the fence keeps cattle out of it, and you keep a backup if one trough goes offline, provided troughs can be isolated. The other is a stand alone trough on the bottom fence line near the cattle lane or drain, because overflow, spillage and flushing water then go straight out of the pen.
Do not put a trough near the feed trough. Cattle drink soon after feeding and carry grain across, so those troughs need cleaning more often, and flushing water plus heavy traffic wears out the pen floor there. Never place a trough where it blocks drainage from the pen.
Cleaning access and aprons
Concrete aprons should be at least 3 m all around the trough, which gives full access and supports the full 2.4 m width of pen cleaning machinery. Troughs are installed level but pens are not, so there is 150 mm fall over a 5 m long trough in a 3% pen, and the apron grade has to vary around the trough. Troughs should also be enclosed underneath, with vertical external sides running from the top of the trough down to the apron, because open frames let manure build up where it cannot be removed.
Where a self flushing trough sits in this
Manufacturer figures for the SATURN trough: 2,225 mm long, 1,950 mm of drinking length, a 50 litre volume, a drain at the far end, and about 60 litres per flush at an interval you set, with one to two flushes a day suggested. It needs 200 to 1,000 kPa of supply pressure. That fits the low volume, long and shallow pattern the manual describes, with its own drainage outlet, though the apron and the drainage run are still yours to sort out.
What we recommend
Settle your drinking length and your drainage point before you buy anything, because a trough is easy to change later and an apron or sewer line is not. If you already empty troughs by hand every day or two, a trough that flushes on a schedule is worth testing on your own farm against the one it replaces. Trials run for 3 months in Victoria, beside your existing water, and we agree in writing how it will be judged before it starts.
- Agriculture Victoria, Water supply in stock containment areas (agriculture.vic.gov.au)
- Meat & Livestock Australia, Feedlot design manual, chapter 20 Water trough design and sewer systems (2016)
- Manufacturer information, SATURN trough specifications (cleantrough.com.au/product)