If you are building numbers this spring, settle two water questions before the extra stock arrive: can your supply deliver the peak daily demand of the new total in four hours, and is there enough accessible trough edge for them all to drink. Both are cheap to check on paper now and awkward to fix once the stock are in the paddock or pen.

Start with demand per head

Agriculture Victoria lists maximum water consumption by class of stock. Peak demand is what you size the system on.

  • Dry sheep: peak 10 L per head per day, average 6 L
  • Lactating ewes: peak 14 L, average 10 L
  • Weaner lambs: peak 6 L, average 4 L
  • Dry cattle: peak 100 L per head per day, average 80 L
  • Lactating cattle: peak 120 L, average 100 L
  • Weaner calves: peak 70 L, average 55 L

Class matters as much as head count. The guide notes that use also varies with breed, type, age and weight, that female stock have an increased demand during pregnancy and lactation, and that feed type, walking distance, shade and the temperature of the water all move the figure. Season moves it too: a mature sheep on dry feed in summer might use 8 to 10 L a day, the same animal on dry feed in winter less than 4 L.

The supply has four hours to deliver it

A reticulated system needs to deliver the daily peak demand in 4 hours, so all stock get a chance to drink on a regular basis. The worked examples in the guide are a minimum flow rate of 21 L per minute for 500 dry sheep and 67 L per minute for 160 dry cattle. The guide also suggests a supply fed by gravity where possible, with at least 4 days of storage in reserve.

Count accessible trough edge, not trough length

For 500 sheep or 160 cattle, Agriculture Victoria says a suitable trough would typically have 8 to 10 metres of accessible trough edge with a storage capacity of 400 to 600 litres. The MLA feedlot manual puts it per head: a minimum of 25 mm per head of linear trough space in normal weather, and 75 mm per head in hot conditions. The manual also makes the point that available length is the trough length less the length lost to float protection, so measure the edge stock can actually reach rather than the outside of the trough.

Pipes sized for every outlet at once

The guide is specific that pipes and fittings need to be large enough to meet peak flow rates simultaneously at all outlets. This is where adding stock often bites: a line that kept one trough full will not necessarily keep two full while both are being drunk down at the same time of day.

More stock, faster fouling

Agriculture Victoria advises emptying, cleaning and refilling troughs every 1 to 2 days, and skimming surface material off the water daily. It also notes stock avoid or reduce consumption of water that is warm, stagnant, polluted with food residues, or has dust or straw floating on the surface. More head puts more of that in the trough, sooner.

Three things make the extra cleaning quicker. A long shallow trough with a smooth internal profile, a gate valve and a large outlet bung. A raised pad of gravel, stone or concrete for drainage and stability, with troughs sited away from feeding areas. And, for cattle, the MLA points on drainage: a large drainage outlet positioned so the water runs away from the trough, an overflow standpipe or sewer line so a jammed float does not flood the pen, and closed-in sides down to the apron so manure cannot build up underneath.

One option: a trough that flushes itself

The SATURN trough is one way to cover the extra cleaning. Manufacturer figures: 50 litre volume, 1,950 mm drinking length, approximately 60 litres per flush, with one to two flushes a day suggested depending on stock numbers. It runs on 200 to 1,000 kPa (2 to 10 bar), takes about 30 minutes to install beside an existing supply, and can be relocated between paddocks as stock rotate. Check the drinking length against the 8 to 10 metres of accessible edge figure to see how many watering points your new numbers need.

What we recommend

Do the demand, flow rate and trough edge sums on your new head count before the stock arrive, not after. If hand cleaning is the part that will not scale, try a self-flushing trough on your own farm for 3 months alongside your existing water and judge it on what you record. Trials are in Victoria, and if it does not suit you can send it back within the 3 months.